Release November 2011-11-25
---------------------------
Added support for parameter ORA that controls report format for #C85 (works like #C5)
Added support for parameter LBE that can be used to disabled low battery reports
Added support for user defined message for #C85 response to keep it different from #C5

Release November 2011-11-16
---------------------------
Fixed issue with reading current profile

Release September 2011-09-30
----------------------------
Enabled button "Deselect all parameters"
Current Profile is shown when unit is connected and #P95 response is aquired from unit or text file
IMEI/IMSI/Info is shown when unit is connected and #P0 response is aquired from unit or text file
Call-button number can be set in Alarm/Report Receivers tab under Status check numbers, to make it easier when status check is set to make call to the callbutton number
Note that it's Alarm call numbers that are used for one of the call options for status check
Generate #C25 after #C2 to make sure unit has updated numbers before TSS is set

Release September 2011-09-26
----------------------------
Updated to support news and changes for GSW 4.2.4 for SRT306 and derivations

Added displaying of information about the unit when reading settings
Removed parameters RSI, NGI and RTS (related to logging) as they were only temporary and has been removed from final release of new firmware
Renamed parameter MTS to SMX (related to logging)
Added support for OVLS Text feed (parameters TFD, TFW and TFA)
Added support for customizing OVLS priority and type codes
Added support for motion detection sensor sensitivity (parameters MDS, MDC, TRS and TRC)
Added ability to switch profile
Changed #C17 generation to make command as long as possible (SMS length limit) instead of one command per message
Removed explicitly asking unit for #C42 as the response is already included in #C14

Known issues:
Translations for some parts of the program is missing
When program runs command #C43*00? against unit, unit may give an error if the unit does not support the command
When program tries to set certain settings, unit may give an error if the unit does not support the settings

Other:
See SRT# Command Specification document for more information about parameters mentioned

Release December 2012-12-19
---------------------------
Remove support for parameter SAR in #C91 for now as it causes problems when reading/writing settings from/to SRT306 X12

Known issues:
Translations for some parts of the program is missing
When program runs command #C43*00? against unit, unit may give an error if the unit does not support the command
When program tries to set certain settings, unit may give an error if the unit does not support the settings
IMEI number is only read properly in some cases

Other:
See SRT# Command Specification document for more information about parameters mentioned

When disabling distance reports using GPS->Distance Report Settings->Enable distance reports?
You should also disable heading change using GPS->Distance Report Settings->Heading Change Enable

Important!
There are many new settings available in newer firmware versions that are not yet supported by the configuration program.
There is currently no timeframe for when these will be added.

Release February 2013-02-13
---------------------------
Fix issue with reference cell input

Release March 2013-03-11
------------------------
Added support for parameter TST (Test Larm Disable, requires at least GSW 4.4.0 and PSW B.6)
Added support for parameter DIC
Added support for parameter GCH (GPS Sleep Mode if charger connected, requires at least GSW 4.4.0 and PSW B.6)
Added support for ManDown parameters (Requires a SRT306X12 with ManDown module)
Added support for SMS filters (parses RMx, generates MASK=, requires at least GSW 4.2.0)
Added support for IP filters (requires at least GSW 4.4.0)
Added support for conditional periodic reporting (requires at least GSW 4.4.0)
Added button to check IMEI
IMEI is now always displayed after read configuration is finished

Known issues:
Translations for some parts of the program is missing
When program runs command #C43*00? against unit, unit may give an error if the unit does not support the command
When program tries to set certain settings, unit may give an error if the unit does not support the settings

Other:
See SRT# Command Specification document for more information about parameters mentioned

When disabling distance reports using GPS->Distance Report Settings->Enable distance reports?
You should also disable heading change using GPS->Distance Report Settings->Heading Change Enable

Important!
There are many new settings available in newer firmware versions that are not yet supported by the configuration program.
There is currently no timeframe for when these will be added.

Release March 2013-03-26
------------------------
Quick fix to make sure all three SMS filters are checked if any of them is checked.

Release March 2013-03-27
------------------------
Add support for user defined and ovls code for the following message types:
Access Alarm/Test
GeoFence Exit
Heartbeat
ManualStop
ManDown
InRange
OutOfRange

Release April 2013-04-25
------------------------
Add support for GPS Extended (limited to newer firmwares)
Fix issue in which callbutton number was not always checked when reading settings

Release December 2014-12-10
---------------------------
Fix parser problems with certain commands

Release December 2014-12-18
---------------------------
Expand passivity alert option

Release January 2015-01-14
--------------------------
Added options to enable/disable always enabled for Mandown alarm and Passivity alarm

Release March 2015-03-05
------------------------
Fix parsing errors with SPT and STT parameters

Release June 2015-06-16
-----------------------
Added support for #C60, #C61 and partial #C83

Release May 2016-05-18
----------------------
Added button to set unit defaults
Colorize some parts to indicate they belong together